LIQUIFIX™

Leading-edge atraumatic hernia mesh fixation devices designed to minimise complications for patient safety and comfort.

LIQUIFIX™ atraumatic mesh fixation for both open and minimally invasive inguinal and femoral hernia repair.

LIQUIFIX™ atraumatic fixation devices affix mesh and peritoneal tissue with liquid anchors, designed to eliminate the need for penetrating mechanical tacks, sutures, or staples. LIQUIFIX™ devices deliver a precise and controlled application of adhesive, designed for patient safety and comfort whilst reducing the risk of some post-operative complications.

Key Features & Benefits

Product performance

Higher shear strength than an advanced tacker 

Minimizing the risk of mesh migration after fixation

Fast set time ≤10 seconds

Managing overall surgical procedure times

Non tissue penetrating mesh fixation

Leading to lower chances of nerve, blood vessel, and tissue damage

Surgical confidence

High lap shear strength for mesh fixation average ≥ 4 N

Ensuring strong and secure mesh fixation

Compatible with the most common used mesh material1

Facilitating the normal process of fibrosis and integration of mesh

Revolutionary design & control

Non-stick atraumatic applicator tip 

Allows fixation at multiple angles

Precise and controlled application of 40+ 12.5mg liquid anchors

Avoids tissue adhesive wastage

Pre-assembled device

Designed for simple and easy handling

Strong mesh fixation

Proven to have a higher shear strength when compared to advanced tacking device.

Strong mesh fixation

Proven to have a higher shear strength when compared to advanced tacking device.

LIQUIFIX FIX8™

LIQUIFIX FIX8™ is designed for laparoscopic hernia surgery and features a 355mm cannula allowing for the precise and controlled application of 40+ liquid anchors. The preassembled device offers users an innovative, atraumatic applicator tip and simple, easy handling.

LIQUIFIX Precision™

LIQUIFIX Precision™ Open is developed for open hernia surgery. Its ergonomic design allows for the precise placement of up to 45 liquid anchors. The innovative, atraumatic tip provides strong and secure mesh fixation at multiple angles.

Intraoperative Benefits

Intraoperative Benefits

LIQUIFIX™ atraumatic fixation devices provide strong and secure mesh fixation even in sensitive areas like the Triangle of Pain, Triangle of Doom, and around the hernia defect

In addition to mesh fixation, LIQUIFIX™ can also be used to close the peritoneum with no mechanical trauma

Compared to an absorbable tacker device, LIQUIFIX™ demonstrates higher lap shear strength, minimising the risk of mesh migration after fixation

Patient Centric Design

Patient Centric Design

LIQUIFIX™ delivers atraumatic mesh fixation

Designed to minimize complications for patient safety and comfort with an improvement in pain from baseline to 6-months post-hernia repair

A reduced risk of common post-operative complications

Low incidence of post-operative chronic pain2

Allows for mesh fixation over areas considered too sensitive for mechanical fixation, such as nerves or blood vessels

Performance

6N

N=6 in all groups (In vivo)

Stronger fixation

Proven to have higher burst strength at mesh fixation than tackers.

LIQUIFIX™ Burst Strength vs Tacking Devices

Pressure (mm Hg)

Downloads

LIQUIFIX™ Non-Penetrating Fixation
LIQUIFIX Precision™ Open Patient Info
LIQUIFIX FIX8™ Patient Info

Contact us for more information

    References

    1 Indicated for polypropylene and polyester mesh in the US

    2 Based on laparoscopic studies